Important: Our new home for AFM probes is launching. The US and Canada is now served at estore.oxinst.us . Australia, India, Singapore, South Korea, and Taiwan are served at estore.oxinst.com . You must create a MyOI account to use the store, instructions here . If you have any questions or concerns please contact: Dominic.Paszkeicz@oxinst.com
0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Search results for '🎗 How Often Do You Give Ivermectin For Mange 🆗 www.Ivermectin4Sale.com 🆗 Ivermectin In Rat 🍃 Ivermectin For Intestinal Worms Dos'

Maximum Search query length is 128. Your query was cut.
Maximum words count is 10. In your search query was cut next part: www.Ivermectin4Sale.com In Rat 🍃 Intestinal Worms Dos.

Set Ascending Direction

   

Items 1 to 50 of 84 total

  1. 1
  2. 2
  1. PPP-NCLAu

    Conductive silicon probe with long cantilever for conductive measurements.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: Au

    Starting at: $384.00

  2. PPP-NCHPt

    Conductive probe for electrical measurements.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $449.00

  3. PPP-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  4. Arrow NCPt

    Silicon probe with PtIr coating for contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $407.00

  5. NW-AR5-NCLR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $839.00

  6. AC55TS

    Fast silicon probe with visible apex tip for fast imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1600 kHz   |   k = 85 N/m   |   tip coating: none

    Starting at: $325.00

  7. PPP-NCST

    Silicon probe with no reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  8. AR10T-NCH

    Silicon probe with high aspect ratio (>10) tip for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  9. SSS-NCLR

    Silicon probe with sharp tip and long cantilever for high resolution imaging in tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $757.00

  10. NW-CDT-NCLR

    Nanoworld silicon probe with long cantilever and conductive diamond coating for tapping/non-contact mode.
    f = 210 kHz   |   k = 72 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  11. NM-RC-C

    Specially designed probes for high mechanical loads and scratch testing applications. Each probe comes with a calibrated spring constant and high resolution SEM showing the tip radius and cone angle.
    f = 750 kHz   |   k = 350 N/m   |   tip coating: diamond tip

    Starting at: $1,500.00

    Ships in 4 Weeks

  12. PPP-NCHR

    Silicon probe with Al reflective coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  13. ATEC-EFM

    Conductive probe with visible tip apex for electrical measurements in modulation mode.
    f = 85 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $890.00

  14. PPP-LC-MFMR

    Silicon probe coated with low coercivity material for MFM on soft magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $691.00

  15. NCL

    Silicon probe with long cantilever and no reflex coating for tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $307.00

  16. NW-AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  17. AC160TS-R3

    Also known as OTESPA; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $360.00

  18. PPP-XYNCHR

    Silicon probe with XY-auto-alignment probes for non-contact /tapping mode application.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  19. AR10-NCH

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  20. SSS-NCHR

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $757.00

  21. ASYELEC.02-R2

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: $407.00

  22. AD-40-AS

    with an apex sharp conductive single crystal diamond tip for high resolution topography and electrical imaging with long tip lifetime.
    f = 180 kHz   |   k = 40 N/m   |   tip coating: diamond tip

    Starting at: $1,000.00

    Ships in 4 Weeks

  23. PPP-NCHAu

    Conductive silicon probe with Au tip coating for electrical measurements in non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Au

    Starting at: $384.00

  24. DT-NCHR

    Silicon probe with diamond coated tip for tapping/non-contact mode on tip degrading samples.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: diamond

    Starting at: $1,185.00

  25. AR5T-NCH

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  26. NCH

    Silicon probe with no reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $307.00

  27. NW-DT-NCHR

    Silicon probe with diamond coated tip for tapping/non-contact mode on tip degrading samples.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: diamond

    Starting at: $1,119.00

  28. PPP-QNCHR

    Silicon probe with high Q and Al reflective coating for tapping/non contact mode in vacuum.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $640.00

  29. PtSi-FM

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: PtSi

    Starting at: $1,481.00

  30. SSS-QMFMR

    Silicon probe coated with thin magnetic material for high resolution MFM in vacuum.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $1,334.00

  31. NW-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $615.00

  32. NW-SSS-NCL

    Silicon probe with sharp tip and long cantilever for high resolution imaging in tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $699.00

  33. PL2-NCH

    Silicon probe with plateau tip for non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  34. CDT-NCHR

    Silicon probe with conductive diamond coated tip for electrical measurements.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,481.00

  35. AR5-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  36. Arrow NC

    Silicon probe with tip at the end of cantilever and no reflex coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $297.00

  37. PL2-NCLR

    Silicon probe with plateau tip with Al reflex coating.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $889.00

    Ships in 1-2 Weeks

  38. PPP-NCLAuD

    Silicon probe with long cantilevr and Au reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  39. PPP-NCLPt

    Conductive probe with long cantilever for electrical measurements.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: Pt/Ir

    Starting at: $449.00

  40. PPP-QLC-MFMR

    Silicon probe coated with low coercivity material for MFM in vacuum.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $1,185.00

  41. NCHPt

    Silicon probe with PtIr coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $419.00

  42. NW-AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  43. ATEC-NC

    Silicon probe with visible tip apex.
    f = 335 kHz   |   k = 45 N/m   |   tip coating: none

    Starting at: $445.00

  44. PPP-NCSTAuD

    Silicon probe with Au reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  45. AR10T-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  46. TL-NCH

    Tipless cantilever.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  47. NW-CDT-NCHR

    Nanoworld silicon probe with conductive diamond coating for tapping/non-contact mode.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  48. NM-TC

    Specially designed probes for high mechanical loads and scratch testing applications. For a similar probe but with a higher resolution tip, see NM-RC
    f = 750 kHz   |   k = 350 N/m   |   tip coating: diamond tip

    Starting at: $750.00

    Ships in 4 Weeks

  49. PPP-NCL

    Silicon probe with long cantilever for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  50. ATEC-NCPt

    Conductive probe with visible tip apex for electrical measurements.
    f = 335 kHz   |   k = 45 N/m   |   tip coating: Pt/Ir

    Starting at: $890.00

Set Ascending Direction

   

Items 1 to 50 of 84 total

  1. 1
  2. 2