  1. AC160TS-R3

    Also known as OTESPA; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $350.00

  2. AC160TSA-R3

    OTESPA with Au reflective coating; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $400.00

  3. AC55TS

    Fast silicon probe with visible apex tip for fast imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1600 kHz   |   k = 85 N/m   |   tip coating: none

    Starting at: $300.00

  4. NCHPt

    Silicon probe with PtIr coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $419.00

  5. NCHR

    Silicon probe with Al reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $307.00

  6. NW-SSS-NCH

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $699.00

  7. 25Pt200B-H

    Solid platinum probe for electrical measurements.
    f = 100 kHz   |   k = 250 N/m   |   tip material: Pt

    Starting at: $400.00

    In Stock

  8. NW-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $615.00

  9. NW-CDT-NCHR

    Nanoworld silicon probe with conductive diamond coating for tapping/non-contact mode.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  10. NCH

    Silicon probe with no reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $279.00

  11. NW-AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  12. Arrow NC

    Silicon probe with tip at the end of cantilever and no reflex coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $245.00

  13. NW-AR5-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $839.00

  14. NCLPt

    Silicon probe with long cantilever and PtIr coating for tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: PtIr

    Starting at: $419.00

  15. NW-CDT-NCLR

    Nanoworld silicon probe with long cantilever and conductive diamond coating for tapping/non-contact mode.
    f = 210 kHz   |   k = 72 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  16. Arrow NCPt

    Silicon probe with PtIr coating for contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $370.00

  17. Arrow NCR

    Silicon probe with tip at the end of cantilever and Al reflex coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $270.00

  18. NW-AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  19. NW-DT-NCLR

    Silicon probe with diamond coated tip and long cantilever for tip degrading samples.
    f = 210 kHz   |   k = 72 N/m   |   tip coating: diamond

    Starting at: $1,119.00

  20. NW-AR5-NCLR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $839.00

  21. NCL

    Silicon probe with long cantilever and no reflex coating for tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $279.00

  22. NW-SSS-NCL

    Silicon probe with sharp tip and long cantilever for high resolution imaging in tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $699.00

  23. NW-DT-NCHR

    Silicon probe with diamond coated tip for tapping/non-contact mode on tip degrading samples.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: diamond

    Starting at: $1,119.00

  24. NW-S-MFMR

    Silicon probe coated with low moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $615.00

  25. NCLR

    Silicon probe with long cantilever and Al reflex coating for tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $307.00

  26. HA100WS

    silicon nitride sharpened wedge tip for tapping mode in liquid.
    f = 160 kHz   |   k = 15 N/m   |   tip coating: none

    Starting at: $1,750.00