0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Probes

Set Ascending Direction

   

Items 1 to 50 of 87 total

  1. 1
  2. 2
  1. AC160TS-R3

    Also known as OTESPA; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $360.00

  2. PtSi-FM

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: PtSi

    Starting at: $1,481.00

  3. AC55TS

    Fast silicon probe with visible apex tip for fast imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1600 kHz   |   k = 85 N/m   |   tip coating: none

    Starting at: $325.00

  4. ASYELEC.02

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 300 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: $350.00

  5. AC160TSA-R3

    OTESPA with Au reflective coating; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $410.00

  6. ASYELEC.02-R2

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: $350.00

  7. AD-40-AS

    with an apex sharp conductive single crystal diamond tip for high resolution topography and electrical imaging with long tip lifetime.
    f = 180 kHz   |   k = 40 N/m   |   tip coating: diamond tip

    Starting at: $1,000.00

    Ships in 4 Weeks

  8. PPP-NCHR

    Silicon probe with Al reflective coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  9. PPP-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  10. PPP-NCSTR

    Silicon probe with Al reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  11. NCHPt

    Silicon probe with PtIr coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $419.00

  12. PPP-NCST

    Silicon probe with no reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  13. AD-40-SS

    Tapping mode probe with a super sharp conductive single crystal diamond tip for high resolution topography and electrical imaging with long tip lifetime.
    f = 180 kHz   |   k = 40 N/m   |   tip coating: diamond tip

    Starting at: $2,000.00

    Ships in 4 Weeks

  14. PPP-NCHAuD

    Silicon probe with Au reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  15. ATEC-NC

    Silicon probe with visible tip apex.
    f = 335 kHz   |   k = 45 N/m   |   tip coating: none

    Starting at: $445.00

  16. AR10T-NCH

    Silicon probe with high aspect ratio (>10) tip for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  17. Quantum-Bio

    Fast scanning probe with full carbon tip; for ultrafast high resolution bioimaging.
    f = 1200 kHz   |   k = 18 N/m   |   tip coating: none

    Starting at: $450.00

    Ships in 3 Weeks

  18. PPP-NCH

    Silicon probe with no reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  19. AR10-NCH

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  20. SSS-MFMR

    Silicon probe coated with thin magnetic material for high resolution MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $1,185.00

  21. 25Pt200B-H

    Solid platinum probe for electrical measurements.
    f = 100 kHz   |   k = 250 N/m   |   tip material: Pt

    Starting at: $400.00

    In Stock

  22. AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  23. NW-CDT-NCHR

    Nanoworld silicon probe with conductive diamond coating for tapping/non-contact mode.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  24. AR10T-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  25. PPP-NCLAuD

    Silicon probe with long cantilevr and Au reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  26. NW-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $615.00

  27. PPP-NCHAu

    Conductive silicon probe with Au tip coating for electrical measurements in non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Au

    Starting at: $384.00

  28. SSS-NCHR

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $757.00

  29. ATEC-EFM

    Conductive probe with visible tip apex for electrical measurements in modulation mode.
    f = 85 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $890.00

  30. PPP-RT-NCHR

    Silicon probe with rotated tip and Al reflective coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  31. NCHR

    Silicon probe with Al reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $307.00

  32. AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  33. PPP-NCL

    Silicon probe with long cantilever for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  34. NW-AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  35. PPP-LC-MFMR

    Silicon probe coated with low coercivity material for MFM on soft magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $691.00

  36. AR5-NCH

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  37. PPP-NCLR

    Silicon probe with long cantilever and Al reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  38. CDT-NCHR

    Silicon probe with conductive diamond coated tip for electrical measurements.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,481.00

  39. AR5T-NCH

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  40. NW-SSS-NCH

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $699.00

  41. SSS-NCH

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $699.00

  42. PPP-LM-MFMR

    Silicon probe coated with low moment material for MFM on magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  43. PPP-NCSTAuD

    Silicon probe with Au reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  44. AR5-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  45. NCH

    Silicon probe with no reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $279.00

  46. Arrow NCPt

    Silicon probe with PtIr coating for contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $370.00

  47. Arrow NC

    Silicon probe with tip at the end of cantilever and no reflex coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $245.00

  48. NW-AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,259.00

  49. AR5-NCLR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $889.00

  50. Arrow NCR

    Silicon probe with tip at the end of cantilever and Al reflex coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $270.00

Set Ascending Direction

   

Items 1 to 50 of 87 total

  1. 1
  2. 2