Important: Our new home for AFM probes is launching. The US and Canada is now served at estore.oxinst.us . Australia, India, Singapore, South Korea, and Taiwan are served at estore.oxinst.com . You must create a MyOI account to use the store, instructions here . If you have any questions or concerns please contact: Dominic.Paszkeicz@oxinst.com
0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Probes

Set Ascending Direction

   

12 Item(s)

  1. AC10DS

    BioLever fast (also known as BL-AC10DS); ultra small cantilever for tapping mode in liquid.
    Only on AFMs with small laser spot such as Cypher.
    f = 1500 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: $600.00

  2. BL-AC40TS

    BioLever Mini; small nitride cantilever with silicon tip for tapping mode in liquid.
    f = 110 kHz   |   k = 0.09 N/m   |   tip coating: none

    Starting at: $500.00

  3. Arrow UHFAuD

    Silicon probe with visible tip apex and Au reflex coating for high speed imaging.
    f = 2000 kHz   |   tip coating: none

    Starting at: $660.00

  4. SSS-FMR

    Silicon probe with sharp tip for high resolution imaging in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $757.00

  5. USC-F0.3-k0.3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 300 kHz   |   k = 0.3 N/m   |   tip coating: none

    Starting at: $980.00

  6. USC-F1.2-k0.15

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 1200 kHz   |   k = 0.15 N/m   |   tip coating: none

    Starting at: $980.00

    Ships in 1-2 Weeks

  7. USC-F5-k30

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 5000 kHz   |   k = 30 N/m   |   tip coating: none

    Starting at: $980.00

  8. USC-F1.2-k7.3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 1200 kHz   |   k = 7.3 N/m   |   tip coating: none

    Starting at: $980.00

  9. USC-F2-k3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 2000 kHz   |   k = 3 N/m   |   tip coating: none

    Starting at: $980.00

  10. SSS-NCHR

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $757.00

  11. USC-F1.5-k0.6

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 1500 kHz   |   k = 0.6 N/m   |   tip coating: none

    Starting at: $980.00

  12. SSS-NCLR

    Silicon probe with sharp tip and long cantilever for high resolution imaging in tapping/non-contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $757.00

Set Ascending Direction

   

12 Item(s)