0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Probes

Set Ascending Direction

   

Items 1 to 50 of 97 total

  1. 1
  2. 2
  1. SSS-FM

    Silicon probe with sharp tip for high resolution imaging in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $757.00

  2. PtSi-FM

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: PtSi

    Starting at: $1,481.00

  3. PPP-NCSTR

    Silicon probe with Al reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  4. qp-CONT

    Quartz like probe with more stability for contact mode.
    f = 30 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: $395.00

  5. PPP-NCHAuD

    Silicon probe with Au reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  6. ATEC-NC

    Silicon probe with visible tip apex.
    f = 335 kHz   |   k = 45 N/m   |   tip coating: none

    Starting at: $445.00

  7. PPP-FM

    Silicon probe with no reflective coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $320.00

  8. qp-BioAC

    Quartz like probe with three cantilevers for contact mode.
    f = 30 & 50 & 90 kHz   |   k = 0.06 & 0.1 & 0.3 N/m   |   tip coating: none

    Starting at: $395.00

  9. AR10T-NCH

    Silicon probe with high aspect ratio (>10) tip for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  10. PPP-NCH

    Silicon probe with no reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  11. PPP-FMR

    Silicon probe with Al reflective coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $320.00

  12. PPP-CONTSCR

    Silicon probe with short cantilever and Al reflective coating for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  13. qp-SCONT

    Quartz like probe with more stability for soft contact mode.
    f = 11 kHz   |   k = 0.01 N/m   |   tip coating: none

    Starting at: $395.00

  14. PPP-NCHR

    Silicon probe with Al reflective coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  15. SSS-FMR

    Silicon probe with sharp tip for high resolution imaging in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $757.00

  16. PPP-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  17. PPP-EFM

    Conductive probe for electrical measurements in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $449.00

  18. PPP-CONT

    Silicon probe without reflective coating for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  19. PPP-NCST

    Silicon probe with no reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  20. qp-BioT

    Quartz like probe with two triangular cantilevers for contact mode.
    f = 20 & 50 kHz   |   k = 0.08 & 0.3 N/m   |   tip coating: none

    Starting at: $395.00

  21. SSS-NCH

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $699.00

  22. CDT-FMR

    Silicon probe with conductive diamond coating for force modulation mode.
    f = 105 kHz   |   k = 6.2 N/m   |   tip coating: conductive diamond

    Starting at: $1,481.00

  23. PPP-FMAuD

    Silicon probe with Au reflective coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $320.00

  24. PPP-CONTSCAuD

    Silicon probe with short cantilever and Au reflective coating for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  25. AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  26. AR5-NCH

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  27. PPP-NCLR

    Silicon probe with long cantilever and Al reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  28. ATEC-EFM

    Conductive probe with visible tip apex for electrical measurements in modulation mode.
    f = 85 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $890.00

  29. ATEC-CONT

    Silicon probe with visible tip apex for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $445.00

  30. PPP-LM-MFMR

    Silicon probe coated with low moment material for MFM on magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  31. SSS-NCHR

    Silicon probe with sharp tip for high resolution imaging in tapping/non-contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $757.00

  32. CDT-NCHR

    Silicon probe with conductive diamond coated tip for electrical measurements.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,481.00

  33. SSS-MFMR

    Silicon probe coated with thin magnetic material for high resolution MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $1,185.00

  34. PPP-CONTAuD

    Silicon probe with Au reflective coating for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  35. AR5-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $889.00

  36. AR10-NCH

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  37. PPP-NCSTAuD

    Silicon probe with Au reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  38. AR5T-NCH

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  39. ATEC-FM

    Silicon probe with tip visible at end of lever for force modulation.
    f = 85 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $445.00

  40. AR10T-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $2,002.00

  41. PPP-NCLAuD

    Silicon probe with long cantilevr and Au reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  42. PPP-NCHAu

    Conductive silicon probe with Au tip coating for electrical measurements in non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Au

    Starting at: $384.00

  43. PPP-RT-FMR

    Silicon probe with rotated tip for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $320.00

  44. PPP-RT-CONTR

    Silicon probe with rotated tip and Al reflective coating for contact mode.
    f = 13 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  45. PPP-LC-MFMR

    Silicon probe coated with low coercivity material for MFM on soft magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $691.00

  46. PPP-CONTR

    Silicon probe with Al reflective coating for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  47. PPP-RT-NCHR

    Silicon probe with rotated tip and Al reflective coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  48. AR10-NCHR

    Silicon probe with high aspect ratio tip (>10) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  49. PPP-NCL

    Silicon probe with long cantilever for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  50. PtSi-NCH

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: PtSi

    Starting at: $1,481.00

Set Ascending Direction

   

Items 1 to 50 of 97 total

  1. 1
  2. 2