The Asylum Research Store and Support will be closed for the holidays 12/20/2019 - 1/2/2020

0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Probes

Set Ascending Direction

   

Items 1 to 50 of 105 total

  1. 1
  2. 2
  3. 3
  1. AC200TS

    Silicon probe with visible apex tip for force modulation or soft tapping on medium to hard samples.
    f = 150 kHz   |   k =9 N/m   |   tip coating: none

    Starting at: $360.00

  2. AC240TS-R3

    Also known as OLTESPA; medium soft cantilever for topgraphy and viscoelasticity of soft samples.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: none

    Starting at: $360.00

  3. BL-AC40TS

    BioLever Mini; small nitride cantilever with silicon tip for tapping mode in liquid.
    f = 110 kHz   |   k = 0.09 N/m   |   tip coating: none

    Starting at: $500.00

  4. AC160TS-R3

    Also known as OTESPA; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $360.00

  5. ASYELEC.01-R2

    Asylum electrolever with visible tip apex and conductive coating for nano-electrical measurements
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Ti/Ir

    Starting at: $350.00

  6. AC10DS

    BioLever fast (also known as BL-AC10DS); ultra small cantilever for tapping mode in liquid.
    Only on AFMs with small laser spot such as Cypher.
    f = 1500 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: $600.00

  7. ASYMFMHM-R2

    Silicon probe with visible tip apex and magnetic coating for high moment MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: $375.00

  8. AC160TSA-R3

    OTESPA with Au reflective coating; silicon probe with visible apex tip for tapping mode.
    f = 300 kHz   |   k = 26 N/m   |   tip coating: none

    Starting at: $410.00

  9. AC10FS

    BioLever fast with CNF tips (also known as BL-AC10FS); Carbon Nano Fiber probe for high resolution imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1500 kHz   |   k = 0.1 N/m   |   tip coating: none

    Starting at: $2,800.00

  10. ASYELEC.02-R2

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 285 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: $350.00

  11. Arrow UHFAuD

    Silicon probe with visible tip apex and Au reflex coating for high speed imaging.
    f = 2000 kHz   |   tip coating: none

    Starting at: $600.00

  12. AC240TM-R3

    Also known as OSCM; conductive probe with visible apex tip for electrical measurement.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: Ti/Pt

    Starting at: $400.00

  13. ASYMFMLC-R2

    Silicon probe with visible tip apex and magnetic coating for low coercivity MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: permalloy

    Starting at: $375.00

  14. AC55TS

    Fast silicon probe with visible apex tip for fast imaging.
    Only on AFMs with small laser spot such as Cypher.
    f = 1600 kHz   |   k = 85 N/m   |   tip coating: none

    Starting at: $325.00

  15. AC240TSA-R3

    OLTESPA with Au reflective coating; medium soft cantilever for topography and viscoelasticity of soft samples.
    f = 70 kHz   |   k = 2 N/m   |   tip coating: none

    Starting at: $410.00

    In Stock

  16. ASYELEC.02

    Asylum electrolever with visible tip apex and conductive coating for tapping/non-contact mode.
    f = 300 kHz   |   k = 42 N/m   |   tip coating: Ti/Ir

    Starting at: $350.00

  17. ASYMFM-R2

    Silicon probe with visible tip apex and magnetic coating for standard MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: $325.00

  18. PtSi-FM

    Sharp conductive probe with PtSi coating for electrical measurements.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: PtSi

    Starting at: $1,481.00

  19. ASYMFMLM-R2

    Silicon probe with visible tip apex and magnetic coating for low moment MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoCr

    Starting at: $375.00

  20. ASYMFMHC-R2

    Silicon probe with visible tip apex and magnetic coating for high coercivity MFM applications.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoPt/FePt

    Starting at: $450.00

  21. SMIM150-G5

    Nitride probe with shielded co-axial sensor specialized for sMIM applications.
    f = 75 kHz   |   k = 8 N/m   |   tip coating: TiW/Au

    Starting at: $750.00

  22. NCSTR

    Silicon probe with Al reflex coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $307.00

  23. EFM

    Silicon probe with PtIr coating for force modulation.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $419.00

  24. PPP-EFM

    Conductive probe for electrical measurements in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: Pt/Ir

    Starting at: $449.00

  25. SMIM300-G5

    Nitride probe with shielded co-axial sensor specialized for sMIM applications.
    f = 19 kHz   |   k = 1 N/m   |   tip coating: TiW/Au

    Starting at: $750.00

  26. SSS-FMR

    Silicon probe with sharp tip for high resolution imaging in force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $757.00

  27. NCHPt

    Silicon probe with PtIr coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: Pt/Ir

    Starting at: $419.00

  28. PPP-NCHAuD

    Silicon probe with Au reflex coating for tapping/non contact mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $320.00

  29. FMR

    Silicon probe with Al reflex coating for force modulation mode.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: none

    Starting at: $307.00

  30. ASYMFMSMPL

    Five each of Asylum MFM levers (ASYMFM; ASYMFMHC-R2; ASYMFMHM; ASYMFMLC; ASYMFMLM); Veeco equiv - MESPSP

    Starting at: $1,700.00

  31. PPP-NCSTR

    Silicon probe with Al reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  32. PPP-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  33. NCHR

    Silicon probe with Al reflex coating for tapping/non-contact mode.
    f = 320 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $307.00

  34. CDT-NCHR

    Silicon probe with conductive diamond coated tip for electrical measurements.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,481.00

  35. USC-F5-k30

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 5000 kHz   |   k = 30 N/m   |   tip coating: none

    Starting at: $980.00

  36. PPP-LC-MFMR

    Silicon probe coated with low coercivity material for MFM on soft magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: soft magnetic

    Starting at: $691.00

  37. NW-CDT-NCHR

    Nanoworld silicon probe with conductive diamond coating for tapping/non-contact mode.
    f = 400 kHz   |   k = 80 N/m   |   tip coating: conductive diamond

    Starting at: $1,399.00

  38. CONTSCR

    Silicon probe with short cantilever for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $307.00

  39. USC-F1.2-k0.15

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 1200 kHz   |   k = 0.15 N/m   |   tip coating: none

    Starting at: $980.00

    Ships in 1-2 Weeks

  40. PPP-NCHAu

    Conductive silicon probe with Au tip coating for electrical measurements in non-contact/tapping mode.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: Au

    Starting at: $384.00

  41. SC-20-M

    CoNi side-coated tip silicon probe for high hi-resolution MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: CoNi

    Starting at: $1,025.00

  42. USC-F1.2-k7.3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 1200 kHz   |   k = 7.3 N/m   |   tip coating: none

    Starting at: $980.00

  43. PPP-CONTSCAuD

    Silicon probe with short cantilever and Au reflective coating for contact mode.
    f = 23 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

  44. AR5T-NCHR

    Silicon probe with high aspect ratio tip (>5) for deep trench imaging.
    f = 330 kHz   |   k = 42 N/m   |   tip coating: none

    Starting at: $1,334.00

  45. NW-MFMR

    Silicon probe coated with high moment material for MFM.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $615.00

  46. PPP-NCSTAuD

    Silicon probe with Au reflective coating for soft tapping mode.
    f = 160 kHz   |   k = 7.4 N/m   |   tip coating: none

    Starting at: $320.00

  47. PPP-NCLAuD

    Silicon probe with long cantilevr and Au reflective coating for tapping/non contact mode.
    f = 190 kHz   |   k = 48 N/m   |   tip coating: none

    Starting at: $320.00

  48. USC-F2-k3

    Quartz-like material probe with carbon EBD tip for high speed imaging in tapping/non-contact mode.
    To be used only on AFMs with small laser spot
    f = 2000 kHz   |   k = 3 N/m   |   tip coating: none

    Starting at: $980.00

  49. PPP-LM-MFMR

    Silicon probe coated with low moment material for MFM on magnetic samples.
    f = 75 kHz   |   k = 2.8 N/m   |   tip coating: hard magnetic

    Starting at: $691.00

  50. PPP-CONTAuD

    Silicon probe with Au reflective coating for contact mode.
    f = 15 kHz   |   k = 0.2 N/m   |   tip coating: none

    Starting at: $320.00

Set Ascending Direction

   

Items 1 to 50 of 105 total

  1. 1
  2. 2
  3. 3